Material and Safety Criteria in Chemical Tank Selection

  • Blog
  • Material and Safety Criteria in Chemical Tank Selection
Material and Safety Criteria in Chemical Tank Selection
Share

Material and Safety Criteria in Chemical Tank Selection

Table of Contents

  • Which Technical Criteria Should Be Evaluated in Chemical Tank Selection?
  • What Is the Difference Between AISI 304 and 316L Stainless Steel?
  • How Does Chemical Compatibility Affect Tank Material Selection?
  • How Are Pressure, Temperature, and Capacity Determined in Chemical Tanks?
  • When Do ATEX and PED Come into Play for Chemical Tanks?
  • Which Controls Should Be Performed for the Safe Use of Chemical Tanks?

Which Technical Criteria Should Be Evaluated in Chemical Tank Selection?

Chemical tank selection is not limited to determining the tank’s volume or production material alone. The composition, concentration, temperature, pressure, viscosity of the chemical to be stored or processed, and the operating conditions must be evaluated together.

In the first stage, the purpose for which the tank will be used must be determined. Different intended uses such as storage, mixing, reaction, buffering, or intermediate stocking within the process can change the design requirements of the tank. In tanks where mixing will be performed, the mixer and connection points; in applications requiring heating or cooling, heat exchangers, jackets, or similar heat transfer solutions are also evaluated separately.

Material selection is also one of the fundamental elements of chemical tank design. If stainless steel is to be preferred, material grades such as AISI 304 or 316L should be evaluated not only according to general usage habits but according to the chemical and operating conditions to which the tank will be exposed.

When determining the capacity of the tank, not only the nominal volume but also the working volume, filling level, expansion allowance, and the free space required by the process should be taken into account. The tank’s inlet-outlet connections, valve structure, drainage points, and maintenance access should also be designed together with the process requirements.

What Is the Difference Between AISI 304 and 316L Stainless Steel?

AISI 304 and AISI 316L are two different material grades encountered in stainless steel tanks and process equipment. However, there is no general rule that 316L is automatically suitable for every chemical or that 304 is inadequate in every application. The correct selection must be made based on the properties of the chemical and the operating conditions.

EvaluationAISI 304AISI 316L
General corrosion resistance Provides good resistance in many general applications. Generally offers higher resistance under more demanding corrosion conditions.
Chloride-containing environments Corrosion risk may increase depending on the conditions. May be more advantageous in some chloride-containing environments due to its molybdenum content.
Hygienic process applications Can be used in suitable processes. May be preferred depending on the chemical and process conditions.
Material selection Must be verified with chemical compatibility data. Must be verified with chemical compatibility data.

The fact that 316L material contains molybdenum can provide an advantage in terms of corrosion resistance, especially in some chloride-containing environments. However, material selection should not be made solely by looking at the name of the chemical. Concentration, temperature, contact time, and process conditions must also be included in the evaluation.

In welded stainless steel tanks, in addition to material selection, the welding application and surface quality are also important. Especially in hygienic processes, proper processing of weld zones and obtaining a cleanable surface are important parts of the design.

How Does Chemical Compatibility Affect Tank Material Selection?

Chemical compatibility is one of the most important technical criteria in determining the tank material. The fact that a material is resistant to a particular chemical does not mean that it will show the same performance at different concentrations or temperatures.

For example, chloride-containing solutions can increase the risk of localized corrosion in stainless steels. In processes where strong acids or bases are used, the concentration, temperature, and contact time of the chemical can be decisive in material selection. For solvents, the compatibility of gaskets and other elastomeric components must also be checked together with the tank material.

Therefore, in chemical tank design, making a general classification such as only “acid tank” or “base tank” is not sufficient. The exact composition, concentration, and operating temperature of the chemical to be used must be determined; then the chemical compatibility data of the material manufacturer and the relevant technical documentation must be examined.

The evaluation below provides only a general technical framework; the final material selection must be made by verifying the relevant chemical and process conditions.

Chemical/process conditionKey issue to be evaluatedApproach in material selection
Chloride-containing solutions Localized corrosion and temperature effect Material grade and process conditions must be verified together.
Acidic solutions Corrosion depending on concentration and temperature Chemical compatibility data must be checked.
Basic solutions Concentration and temperature Material suitability must be evaluated according to specific process conditions.
Solvents Compatibility of tank and gasket materials Gaskets and connection elements must also be checked together with the tank material.

How Are Pressure, Temperature, and Capacity Determined in Chemical Tanks?

The operating conditions of the chemical tank affect many design decisions, from tank geometry and equipment selection to safety devices. Therefore, when determining capacity, not only how many liters of product the tank will hold but also under which conditions it will operate must be taken into account.

The design requirements of an atmospheric tank and a tank operating under pressure are not the same. In pressurized applications, design pressure, operating temperature, material properties, connections, and relevant legislation must be evaluated together.

Temperature is also an important parameter that affects material compatibility and equipment performance. Since the behavior of the same chemical can change at different temperatures, material selection must be made taking the operating temperature into account.

When determining capacity, the daily or hourly consumption of the process, filling-emptying frequency, working volume, and required safety margins are evaluated. The tank’s inlet and outlet connections and pump capacity must also be compatible with the process flow.

When Do ATEX and PED Come into Play for Chemical Tanks?

ATEX and PED are not requirements that automatically apply to every chemical tank. Which regulation or standard is valid must be determined according to the operating mode of the tank, pressure and temperature conditions, the substances used, and the risks created by the facility.

ATEX covers the requirements related to equipment and protection systems in environments where there is a possibility of an explosive atmosphere forming. Whether this risk exists during the storage or processing of flammable chemicals must be addressed within the scope of the facility’s risk assessment.

PED (Pressure Equipment Directive) comes into play for certain pressure equipment and pressurized systems. Parameters such as whether the tank operates under pressure, design pressure, volume, and the fluid used are important in the scope assessment.

Therefore, the relevant legislation and standards must be determined at the beginning of the chemical tank project. The requirements that must be applied must be verified according to the technical characteristics of the tank and the usage scenario.

Which Controls Should Be Performed for the Safe Use of Chemical Tanks?

The safe use of chemical tanks does not end with the completion of manufacturing. The tank must be operated in accordance with its operating conditions, and regular inspection and maintenance activities must be carried out.

The tank body, weld zones, connections, gaskets, valves, and other equipment must be inspected according to the determined maintenance program. Since corrosion, surface degradation, or sealing problems may occur depending on the chemical used, the scope of these controls must be determined according to the process conditions.

Level measurement and process control are also important parts of safe operation. Preventing overfilling of the tank, monitoring the operating conditions of pumps and pipelines, and utilizing alarm systems when necessary can support process safety.

In pressurized applications, the suitability of pressure gauges and related safety equipment must also be checked. In facilities where there is a risk of flammable or explosive atmospheres, electrical equipment and other related systems must be compatible with the risk assessment.

When selecting a chemical tank, the correct approach is not to evaluate the tank merely as a storage equipment, but to address chemical compatibility, operating conditions, process flow, safety requirements, and maintenance needs together. In applications where stainless steel tanks are used, material selections such as AISI 304 or 316L must also be made within this technical evaluation framework.