Why ATEX Zone Classification Matters for Pigging Systems
- Blog
- Why ATEX Zone Classification Matters for Pigging Systems
Why ATEX Zone Classification Matters for Pigging Systems
Table of Contents
- What Is ATEX?
- How Zone Classification Is Carried Out
- Difference Between Gas and Dust Zones
- Equipment Categories
- Motors, Sensors and Cabling
- Product Vapour at the Pig Receiver
- Ventilation and Ambient Conditions
- Equipotential Bonding
- Control Panel Placement
- Conclusion
Pigging systems use pressurised fluid and moving elements to clean a product line or recover product. When the product is volatile, combustible or dusty, an explosive atmosphere can form around the equipment. ATEX zone classification is therefore one of the subjects that must be addressed at the very start of a pigging project.
What Is ATEX?
ATEX refers to the European Union directives covering equipment and protective systems intended for use in explosive atmospheres. Similar requirements are applied in other markets through their own regulations and standards. The aim is to prevent ignition sources such as sparks and hot surfaces in areas where an explosive atmosphere may occur.
ATEX compliance should be evaluated not only through the equipment label but also through installation and maintenance practice.
How Zone Classification Is Carried Out
Zone classification is based on how often and for how long a hazardous atmosphere may be present. The plant divides its areas into zones through a risk assessment. This assessment should rely on product properties, ventilation, leak sources and operating conditions.
The classification result directly determines equipment selection, cabling and installation rules. For this reason the classification should be completed in writing by a competent team.
Difference Between Gas and Dust Zones
Hazardous areas caused by gases or vapours and those caused by dust are classified differently. If product vapour can form at the pig receiver, the gas zone should be assessed; if the product contains dust, the dust zone should be assessed. Some plants may face both hazards together.
Equipment selection follows different criteria for each case. For this reason, the physical state of the product must be defined correctly.
Equipment Categories
Equipment covered by ATEX must have a category and a type of protection suited to the zone. The category defines where the equipment may be used. The information on each item's label should be compared with the zone where it will be installed.
The type of protection describes how the equipment controls the risk of ignition from sparks or surface temperature. Selection should be confirmed with manufacturer documentation and an inspection.
Motors, Sensors and Cabling
The motor, sensors, solenoid valves and cabling used in a pigging system must suit the zone classification. Where the sensors detecting the pig passage sit inside the explosive zone, the equipment must be selected accordingly. Cable entries and enclosures must also match the protection level.
In cabling, cable trays, cable entries and seal integrity should be checked. A damaged cable entry can reduce the level of protection.
Product Vapour at the Pig Receiver
The pig receiver is the point where the pig arrives and the product is collected. If the product is volatile, a gas cloud can form inside or around the receiver. This point should be assessed with particular care in the classification study.
When the receiver cover is opened, release of product vapour must be planned for operator safety and environmental conditions. The opening procedure should include pressure relief and ventilation steps.
Ventilation and Ambient Conditions
Ventilation is important for diluting the hazardous atmosphere and preventing it from accumulating. Insufficient ventilation can adversely affect the zone classification. In enclosed areas, ventilation design should be carried out together with the classification study.
Ambient conditions such as temperature, humidity and dust loading also affect equipment selection and maintenance frequency. These conditions should be monitored and recorded.
Equipotential Bonding
Equipotential bonding of metal equipment and lines prevents different potentials from developing and sparks from forming. All metal parts of the pigging system should be connected to a common earth point. Contact points on painted surfaces should be cleaned.
Continuity of the bonds should be measured after installation and periodically. The measurement criteria should be set according to the applicable standard and the plant regulations.
Control Panel Placement
The control panel should, where possible, be located outside the explosive zone or in an area with suitable protection. Electrical components inside the panel must also be selected according to the zone classification. The operator's access to the panel should be provided safely from outside the hazardous area.
Emergency stop buttons and interlock mechanisms should be easy to reach from the panel. The panel location should be documented together with the classification plan.
Conclusion
ATEX zone classification in pigging systems is an assessment that runs from product properties through equipment selection, cabling, earthing and panel placement. When it is done correctly, the system works both efficiently and safely.
SS Proje supports the consideration of the relevant ATEX requirements in the design and manufacture of pigging systems. Final classification and approval depend on the assessment of the competent authorities.